Home             Himgiri-English home

Classified

 

ENERGY & POWER DEPARTMENT

GOVERNMENT OF SIKKIM

KAZI-ROAD, GANGTOK

NOTICE INVITING QUOTATIONS

Sealed quotations are invited from the registered electrical suppliers/dealers/workshop holders for supplying the materials required for the repairing of distribution transformers as per the list enclosed. The quotation should reach to the office of the Superintending Engineer (HQ-II) on or before 20th of December 2007 at 1500 hours.

The quotation shall be open on 24th December 2007 at 14 hours through the departmental opening committee.

The Department reserves the right to reject or accept the quotation without assigning any reason thereof.

Terms & Conditions:

1. The materials should confirm IS mark.

2. The materials should be FOR Gangtok.

3. The rate should be inclusive of all taxes and levies.

SHEDULED OF RATES FOR SUPPLY ITEMS ANNEXURE-A

(rates shall remain Firm during the period of Rate Contract order)

SI.No. Description of item Unit Rate (Rs.)

1. Supply of Bushing in replacement of broken one

(a) 70 KV 250 Amps Each

(b) 12 KV 250 Amps Each

(c) 12 KV 630 Amps Each

(d) 1.1 KV 250 Amps Each

(e) 1.1 KV 650 Amps Each

(f) 1.1 KV 1000 Amps Each

(g) 650 V 250 Amps Each

2. Supply of studs of Brushing complete with Nuts.

Washer and Cap Fittings according to requirement conforming

to IS:3347 (a)Brass stud with Brass fittings complete with Nuts.

Washers & Cap Fittings

(i) 12 KV 250 Amps Per Kg

(ii) 1.1 KV 250 Amps Per Kg

(iii) 1.1 KV 630 Amps Per Kg

(iv) 1.1 KV 1000 Amps Per Kg

(v) 650 V,250 Amps Per Kg

(b) Aluminium stud with Aluminium Fittings complete with

Nuts. Washers etc.

(i) 12 KV 250 Amps Per Kg

(ii) 1.1 KV 250 Amps Per Kg

(iii) 650 V 250 Amps Per Kg

(c) Copper Stud with Copper Fittings complete with Nuts etc.

(i) 12 KV 250 Amps Per Kg

(ii) 1.1 KV 250 Amps Per Kg

(iii) 1.1KV 630 Amps Per Kg

(iv) 1.1 KV 1000 Amps 30mm. Stud Per Kg

(v) 1.1 KV 1000 Ampsm.25mm Stud Per Kg

(d) Brass stud with Brass fitting complete with nuts etc.

34KV/250 Amps Per Kg.

(e) Copper Stud with Brass Fitting complete 34 KV/250A Per Kg

3. Oil seal of Bushings

(i) 1.1 KV 250 Amps Each

(ii) 1.1 KV 650 Amps Each

(iii) 1.1 KV 1000 Amps Each

(iv) 12 KV 250 Amps Each

(v) 70 KV 250 Amps Each

4. Supply of C.I. Clamp for M.S Clamp

(a) 66KV Bushing Per Kg

(b) 11 KV Bushing Per Kg

5. Supply of Arching Horn assembly

(a) 66KV Single Gap Clamp Per Kg

(b) 11 KV Single Gac Clamp Per Kg

6. Supply of Insulating materials for assembly

(a) Phase separator, Spacers axial ducts, cylinders core yoke

insulation

(i) Rammam make sigma con 3.1 pre-compressed press phan

paper board Per Kg

(ii) ‘K" Grade senapatty white lay 0.75mm

Pre-compressed Press Board 1.5mm

3.2mm

5mm

(b) Other (viz Amperetape cotton Tape, Bakelite Tube and

Sleeve Rings) for each Transformer L.S

(a) HV Coils Insulation TPC Per Kg

(b) HV coins Insulations DPC Per Kg

(c) HV Coils Insulation SE Per Kg

(C) 400 Volts Coil:

(a) LV Coil Insulation DPC (Round) Per Kg

(b) LV Coil Insulation IPC (Rectangular) Per Kg

4. Labour Charges for rewinding with re-insulation of existing

(A) Copper Conductor with replacement of inter-layer insulation

(a) 66 KV Coil: TPC/DPC Per Kg

(b) 11 KV/6. 6 KV Coil. DPC/TPC

4. Labour Charges for rewindings without re-insulation of existing

(B) Copper Conductor with replacement of inter-layer insulation

(a) 66 KV Coil: TPC/DPC Per Kg

(b) 11 KV/6. 6 KV Coil. DPC/TPC Per Kg

5. Labour Charges for rewinding with re-insulation with inter layer

Insulation of old Lv:400 Volts Copper Coil with ducting.

(a) LV Coils: Insulation DPC (Round) Per Kg

(b) LV Coil Insulation DPC(Rectangular) Per Kg

(c) LV Coil Insulation SE Per Kg

6. Labour Charges for preparation and fitting of finished new

AI. Coil by providing inter layer insulation

(A) 11/6.6KV/6KV Coils

(a) Insulation DPC (Round) Per Kg

(b) 400 Volts Coil (with ducting)

(a) Insulation DPC (Round) Per Kg

(b) Insulation DPC (Rectangular) Per Kg

7. Labour Charges for rewinding with replacement of inter layer

 Per Kg (A) Insulation of old AI. wire 11/6.6 KV Coils (DPC/SE)

(B) Labour Charges wither-insulation of existing 400 volts LV AI.

Coils by providing new inter layer insulation with ducting.

8. Re-assembly and boxing up of Core and Coil after thorough

cleaning, drying and reconnection of Coils including testing

charges (Double Voltage Double Frequency test included).

(a) 25 KVA,11/6.6/60 433 KV Each

(b) 50/63 KVA,11/6.6/6/0.433 KV Each

(c) 100 KVA,11/6.6/6/0.433 KV Each

(d) 250 KVA, 11/6.6/6/0.433 KV Each

(e) 315 KVA, 11/6.6/6/0.433 KV Each

(f) 500/750 KVA,11/6.6/6/0.433 KV Each

9. External Painting of Transformer

(a) 25 KVA,11/6.6/6/0.433 KV Each

(b) 50/63 KVA, 11/6.6/6/0.433 KV Each

(c) 100 KVA,11/6.6/6/0.433 KV Each

(d) 250 KVA, 11/6.6/6/0.433 KV Each

(e) 315 KVA, 11/6.6/6/0.433 Each

(f) 500/750 KVA,11/6.6/6/0.433 KV Each

(i) For 25 KVA 11/0.433 KV 3Ph

(ii) For 50/63 KVA Transformer

(iii) For 100 KVA Transformer

(iv) For 250 KVA Transformer

(v) For 300/315,KVA Transformer

(vi) For 500 KVA Transformer

(vii For 750 KVA Transformer

7. Supply of Neoprene Rubberized Gasket Sheet: Make Rubber Per.Sq. Mtr

(i) 3mm thickness

(ii) 5mm thickness

(iii) 6mm thickness

8. Ratio switch with handle

(a) (i) 250 KVA 5 position Each

(ii) 250 KVA position Each

(b) (i) 315 KVA 5 position Each

(ii) 315 KVA 7 Position Each

(c) (i) 500 KVA 5 position Each

(ii) 500 KVA 7 Position Each

(d) (i) 750 KVA 5 Position Each

(ii) 750 KVA 7 position Each

9. Supply of finished new E.C. Grade Copper Conductor Per Kg

(i) TPC Per Kg

(ii) DPC Per Kg

(iii) SE Per Kg

Less 5% allowed

10. Supply of finished new E.C. Grade Strip DPc (50 Sq.mm) Per Kg

11. Supply of finished new aluminium conductor coils/Wires

(i) S.E Per Kg

(ii) TPC/DPC Per Kg

12. Supply of finished new Aluminium strip DPC/TPC Per Kg

13. Supply of M.S. Bolts & Nuts (assorted size) according to

requirement (size to be mentioned as per BS916 BSW)

(TATA/GKW make) Kg on each rating

For 25 KVA

For 50/63 KVA For 100 KVA

For 250 KVA

For 300/315 KVA

For 500 KVA

For 750 KVA Rate(Rs)

14. Supply of hot- dip galvanished Nuts Bolts and washers

(TATA/GKW make) Kg on each

rating

For 25 KVA

For 50/63/KVA

For 100 KVA

For 250 KVA

For 300/315 KVA

For 500 KVA

For 750 KBVA

15. Supply of Silicagel Breather with container and first filling

(a) 10/25 KVA 11/6/6/6/0.433 KV Each

(b) 50/63 KVA 11/6/6/6/0.433 KV Each

Unit

(c) 100 KVA 11/6/6/6/0.433 KV Each

(d) 250 KVA11/6/6/6/0.433 KV Each

(e) 315 KVA 11/6/6/6/0.433 KV Each

(f) 500/750 KVA 11/6/6/6/0.433 KV Each

16. Supply of new cooling round pipe including welding & fitting Per Rn.Mtr

17. Supply of Dram Valve/Filter Valve with plug in replacement

of old one Each

(a) 1/4" Each

(b) 3/4" Each

(c) 1" Each

(d) 1 1/4" Each

(e) 1 1/2" Each

(f) 2" Each

18. Salvaged Materials recovery rate for

(i) Barrel/Drum Each

(ii) Scrap Aluminium Kg.

(iii) Scrap Copper Kg.

(iv) Scrap Brass Kg.

19. BASE PLATE WITH FIXING

(i) (The Base Plate is to be made of M.S Material 2.5mm thick L.S for each

measuring 6"X4" to be fixed with the body of the Transformer Transformer of

Tank suitably by welding) different ratings

(ii) NAME PLATE WITH FIXING

(The Name Plate is to be made of anodized AI.0.6mm thick measuring L.S for

each 4"X1" L.S for each. The Name Plate is to be fixed on the base plate Transformer of

by machine screws and welded). different ratings

The Name Plate should indicate the following

(a) Name of the Repairer’s Firm

(b) Name ot the Store wherefrom received

(c) MAKE/Serial No.

(d) Voltage ratio

(e) KVA ratings

(f) % Impedance at 75c

(g) Date of test (The above particulars are to be letter punched on

the Name Plate).

The general lettering should be attached on AI.plate and anodized).

(B) SCHEDULE OF RATES FOR LABOUR & SUPERVISING ONLY

(Rates shall remain Firm during the period of R/C Order)

SI.No. Description of items Unit Rate (Rs.)

1. Joing Survey and preparation of report together with estimate

of repair work involved (to be submitted in quadruplicate)

(a) 25 KVA,11/6/6/6/0.433KV Each

(b) 50/63 KVA,11/6/6/6/0.433KV Each

(c) 100 KVA,11/6/6/6/0.433 KV Each

(d) 250 KVA,11/6/6/6/0.433KV Each

(e) 315 KVA,11/6/6/6/0.433KV Each

(f) 500/750 KVA 11/6/6/6/0.433KV Each

2. Re-assembly of Transformer found condemned

after inspection

(a) 25KVA,11/6/6/6/0.433 KV Each

(b) 50/63 KVA,11/6/6/6/0.433KV Each

(c) 100KVA,11/6/6/6/0.433 KV Each

(d) 250KVA,11/6/6/6/0.433KV Each

(e) 315KVA,11/6/6/6/0.433KV Each

(f) 500/750 KVA,11/6/6/6/0.433KV Each

3. Labour Charges for preparation and fittings of new

Copper Coils in replacement of damaged ones by

providing inter -layer insulation PerKg

(A) 11/6.6/6KV Coils

(a) HV Coils Insulation TPC Per Kg.

(b) HV Coils Insulation TPC Per Kg.

(c) HV Coils Insulation TPC Per Kg

(d) 66 KV Coils

 
 

Home             Himgiri-English home